Don't do full rollback on systems without systemd when tuned is exiting

Fixes commit 701f09a8.

Signed-off-by: Ondřej Lysoněk <olysonek@redhat.com>
This commit is contained in:
Ondřej Lysoněk 2017-09-26 13:03:02 +02:00
parent 7e7b1ee878
commit a4346d2b48

View file

@ -116,12 +116,14 @@ class Daemon(object):
self._application._dbus_exporter.send_signal(consts.DBUS_SIGNAL_PROFILE_CHANGED, profile_names, result, errstr)
return errstr
def _system_shutting_down(self):
def _full_rollback_required(self):
retcode, out = self._cmd.execute(["systemctl", "is-system-running"], no_errors = [0])
if retcode < 0:
return False
if out[:8] == "stopping":
return True
return False
retcode, out = self._cmd.execute(["systemctl", "list-jobs"], no_errors = [0])
return re.search(r"\b(shutdown|reboot|halt|poweroff)\.target.*start", out) is not None
return re.search(r"\b(shutdown|reboot|halt|poweroff)\.target.*start", out) is None
def _thread_code(self):
if self._profile is None:
@ -170,11 +172,11 @@ class Daemon(object):
# stopped by user and in such case do full cleanup, without systemd never
# do full cleanup
full_rollback = False
if self._system_shutting_down():
log.info("terminating Tuned due to system shutdown / reboot")
else:
if self._full_rollback_required():
log.info("terminating Tuned, rolling back all changes")
full_rollback = True
else:
log.info("terminating Tuned due to system shutdown / reboot")
if self._daemon:
self._unit_manager.stop_tuning(full_rollback)