5 of 10 symbol-config tools verified end-to-end on SP22 P1 against MCPTest2: find/create/get_settings/set_settings/list_configured_symbols. 3 timed out and crashed CODESYS with exit 0xFFFFFFFF (set_signature_ access_bulk, export_symbol_xsd, indirectly set_symbol_access) because get_all_signatures(True) and get_symbol_configuration_xsd() trigger an application.build() that aborts on this project (empty PLC_PRG body, IoDrvGPIO managed library). list_all_signatures itself ran cleanly but returned 0 -- not a crash, just a build short-circuit on an empty POU. Re-run on a project with a real, build-clean PLC_PRG body. Tool code itself non-regressing -- the 5 read/write paths that don't trigger a build all worked. |
||
|---|---|---|
| .. | ||
| superpowers | ||
| function-test-2026-04-25.md | ||
| function-test-2026-04-28.md | ||
| migration-sp21-plus.md | ||
| open-bugs-cross-reference.md | ||